This website uses its own and third-party cookies to obtain statistical data and improve navigation. If you accept or continues browsing, it is considered that you accept its use. For more information visit our cookies policy.

[ OK ]

Eris1R

Gamma and X-Rays Radiameter and Dosimeter

  • Gamma and X-Rays detection and measurement, H*(10)
  • Compensated in energy Geiger-Müller detector
  • Small, compact and light-weight
  • Max. dose rate 100 mSv/h
  • Three measurement modes: dose rate, maximum rate (hold), and accumulated dose with accumulation time
  • Two alarm thresholds, in µSv/h and in µSv
  • Self-test with indication of alarms, detector fail, low battery, and out of range


DISCONTINUED!

The new model ERiS2-R
replaces the Eris1R monitor.

The Eris1R is a handheld, compact and lightweight radiation monitor to detect and measure Gamma and X-Rays radiation up to 100 mSv/h, and with an energy range of 40 KeV to 1.3 MeV.

The Eris1R has three measuring modes: the Rate mode to measure the dose rate, the Hold mode to freeze the maximum value of dose rate, and finally, the Dose mode to display the value of the accumulated dose and the accumulation time. Dose and time are stored in the non-volatile memory.

The Eris1R is very easy to use. Its sophisticated firmware calculates the average dose rate of the last seconds correcting the dead time of the detector. This reading is very stable, but it is automatically updated when the radiation field varies more than three times the standard deviation of the previous reading. This does the monitor has a fast response time and stable readings.

The dose rate and accumulated dose have alarm threshold values, that can be set by the user and stored in the non-volatile memory. In case the dose rate or the accumulated dose is above its alarm threshold value, an alarm message will be displayed. Besides, the monitor displays a warning message if the battery level is low, if the detector fails or if the reading is out of range (overflown).

The Eris1R monitor is supplied with a transport case with strap, the user’s manual and a certificate with the results of measures after the calibration (related to Cs137).

Measuring type Gamma and X-Rays, H*(10), in International System units (Sv/h, Sv).
Detector Geiger-Müller, compensated in energy
Measuring modes - Dose rate (Sv/h)
- Accumulated dose (Sv), with acumulation time indication (0.0h-9999h)
- Maximum dose rate (hold)
Indication range Auto-range
- In dose rate: 0.01 µSv/h - 100 mSv/h
- In accumulated dose: 0.00 µSv - 999 mSv
Measuring range 0.1 µSv/h - 100 mSv/h
Gamma sensitivity aprox. 0.75 cps/µSv/h (related to Cs137)
Accuracy ±15% max., in the measuring range
Energy range 40 KeV to 1.3 MeV
Energy dependence Max. ±20% in the energy range (related to Cs137)
Above to ±20% in range 30-40 KeV, and >1.3MeV
Response time Automatic, minimum 1 s. According to 3-Sigma criteria it updates the mesurement if the detected value in last second has a deviation above three times the standard deviation of average value
Display LCD 12x2
LED - Indicator of the frequency of detected events
- Indicator of alarms
Audio Controlled by pushbutton
Keyboard Four membrane pushbuttons, ON/OFF, MENU, AUDIO, RESET
Power Alkaline 9 volts battery. More than 80 hours of continous operation (with a rate < 1 µSv/h).
Dimensions 11.7 x 7.2 x 2.5 cm
Weight 220 g. (with battery)
Temperature range -10ºC a +50ºC
Humidity range max. 90% RH (non condensed).

ERIS1R - Gamma and X-Rays radiameter.

Ref: LAM028V02

It is supplied with the following elements:

  • Eris1R radiameter
  • Transport case with strap.
  • 9V battery
  • User's manual in english
  • Calibration certificate of LAMSE


ACCESORIES:

Transport case for Eris1.

Ref: LAM024V03

with strap.
In new orders, this transport case is already included with any Eris1.

This table shows a comparison between Eris1R and other models of Eris1 family.
ERIS1R
ERIS1C
ERIS1D
Gamma and X-Rays H*(10) measurement
Alpha, Beta, Gamma contamination mesurement
µSv/h unit
CPS unit
Bq/cm² unit
Isotope library (calibration coefficients)
Rate measurement mode
Accumulated dose mode
Maximum rate mode (Hold)
Adjustable alarm threshold in µSv/h
Adjustable alarm threshold in cps
Adjustable alarm threshold in Bq/cm²
Self-testing with indication of alarms, detector fail, battery low level, and out of range
Counter/Timer with adjustable measuring time


Next table shows a comparison between instruments for radiation measurement.
ERiS2-R
ERiS2-M/G
ERiS2-D
RM1001-RD
RM1001B-RD
Gamma and X-Rays H*(10) measurement
Alpha, Beta, Gamma contamination measurement with external sondes
Internal detector Optional Optional Optional
External sondes Optional Optional Optional
Multiprobe
Hand-held
Stationary Optional Optional
Wall holder Optional Optional
Rechargeable battery
External power
Data store Optional
Data Download/Register software Optional

  • Firemen, police and emergency services
  • Hazardous goods transport
  • Research centers
  • Hospitals
  • Universities
  • Radiological protection
  • X-Rays systems
  • Industry with radioactive sources
  • etc...